When a controller sees a number, what does that tell you about the quantity it is trying to control? Start with a small recurrence you can check by hand.

Course topic: Signals, Systems and Control

Study route and exercise: University Reading List editorial project. How we curate · Sources checked:

On this page

Scope and responsibility

This route connects discrete-time signals to feedback and then to the assumptions behind a local joint model. It uses an invented bench simulation. The recurrence, parameters and exercises are original teaching examples.

Choose your starting point

First feedback calculation

Read the proportional term in Åström and Murray, §10.1. Sketch the path from reference through error, controller, plant and sensor.

Study discrete-time models

Use Sadiku and coauthors’ z-transform chapter for recurrence and pole practice. Use the free Adams reading alongside it when needed.

Connect to robot joints

Use Craig’s fourth-edition linear-control chapter after reviewing dynamics. Write down what would change if a second joint moved.

Compare the three books

Feedback Systems: An Introduction for Scientists and Engineers

Karl Johan Åström; Richard M. Murray · Edition: 1 · 2008

Free feedback foundation

Choose it when
You can follow elementary differential or difference equations and want to reason from an error signal to a closed loop.
Use another route when
You first need practice with complex numbers, sequence indexing or the meaning of a pole.
Selected reading
Read chapter 10 §10.1 for proportional action and chapter 5 §5.3 for the difference between transient and steady response. Read Feedback Systems §10.1 for free ↗
Limits and trade-offs
These sections teach concepts that transfer. Use the discrete pole condition for the sampled exercise and the continuous condition only for a continuous model.

Try before choosing

Draw the model’s negative feedback path and label the true output and the measured output separately.

Check your work: Both paths are visible on your diagram and the subtraction uses the measured output.

Official free reading ↗

Book record and access options →

Signals and Systems: A Primer with MATLAB

Matthew N. O. Sadiku; Warsame Hassan Ali; Sarhan M. Musa · Edition: 2 · 2024

Transform and sequence practice

Choose it when
You want to connect a recurrence, a z-domain pole and a calculated response, with MATLAB for repetition.
Use another route when
You need manipulator geometry, inertia coupling or joint control.
Selected reading
Read the second edition’s z-transform chapter and work from a difference equation to a response before running a script. Free parallel reading: Adams §11.15 ↗
Limits and trade-offs
Transform practice makes the model easier to check. The coefficients still need a physical interpretation before using the model on equipment.

Try before choosing

From y[k+1]=0.6y[k]+2 and y[0]=0, compute the first three samples and the limiting value.

Check your work: The samples are 2, 3.2, 3.92 and the limit is 5.

Book record and access options →

Introduction to Robotics: Mechanics and Control

John J. Craig · Edition: 4 · 2022

Transfer to manipulator control

Choose it when
You know rigid-body dynamics and want to see what a local linear feedback model assumes about a joint.
Use another route when
You are learning basic discrete stability or need a free first reading.
Selected reading
Read chapter 6 on dynamics, then chapter 9 on linear control of manipulators in the fourth edition. Free alternative: Åström and Murray §10.1 ↗
Limits and trade-offs
A single-joint linear model is a useful starting point. Real mechanisms can have coupled joints, varying loads and limited actuation.

Try before choosing

List two assumptions needed to use a single recurrence as a joint model and one observation that would challenge each.

Check your work: The observations could reveal coupling, actuator limits or a change in dynamics with position or load.

Book record and access options →

Check your preparation

What changes when a signal is sampled?

The model updates at integer indices k. A discrete pole p corresponds to multiplication by p at each step, so decay requires |p|<1.

Why separate measurement and output?

A sensor reading m can differ from the true y by a constant bias or other effects. The controller acts on the reading it receives.

Does stability imply accurate tracking?

Stability describes perturbations around equilibrium. Tracking error also depends on where the equilibrium lies relative to the reference.

A six-step study plan

These are your own study marks, not an assessment. They are not sent to this site.

  1. Label the loop

    Selected reading: Åström and Murray §10.1.

    What to do: Draw r, m, r−m, u, and y in the signal path.

    Check your work: Point to the value the controller subtracts.

  2. Check a recurrence

    Selected reading: Sadiku’s z-transform chapter or the free Adams text.

    What to do: Compute three samples of a scalar recurrence by hand.

    Check your work: Keep the sample index and initial condition visible.

  3. Close the loop

    Selected reading: Guide example and the proportional term.

    What to do: Substitute the controller into the plant model before finding the pole.

    Check your work: Distinguish the coefficient of y[k] from the constant term.

  4. Compare performance

    Selected reading: Åström and Murray §5.3 and the guide example.

    What to do: Compare the step response and the steady tracking error for two gains.

    Check your work: Report convergence and error separately.

  5. Test the sensor

    Selected reading: Guide follow-up.

    What to do: Compare a biased reading with the true output.

    Check your work: Calculate both errors and explain why the pole is unchanged.

  6. Audit model transfer

    Selected reading: Craig, chapters 6 and 9.

    What to do: Choose one assumption that a simulated tabletop joint may violate, such as one independent axis.

    Check your work: Name a diagnostic observation you would need before changing the model.

Worked exercise

Two gains, two different tracking errors

An invented simulation describes a sampled position readout: y[k+1] = 0.8 y[k] + 0.2 u[k], u[k] = K(10 − y[k]), y[0] = 0. Compare K = 1, 4 and 10. For each find the pole; only where the response converges, report its limit and the error relative to target 10.

Assumptions

Units are normalized. The sensor is unbiased with no delay in this example. Assume fixed coefficients, no clipping and no physical hardware. K = 10 is a deliberately unstable mathematical case.

  1. After substitution the update is y[k+1] = (0.8 − 0.2K)y[k] + 2K. A displacement from the fixed point multiplies by p = 0.8 − 0.2K each sample.
  2. K = 1 gives p = 0.6 and limit 2/(1−0.6) = 5. K = 4 gives p = 0 and limit 8. The corresponding errors are 5 and 2.
  3. K = 10 gives p = −1.2. With y[0] = 0 the initial displacement from the fixed point is nonzero and alternates with growing magnitude, so a steady tracking error cannot be reported.

Answer and interpretation

K = 1 and K = 4 converge to 5 and 8 respectively. K = 10 is unstable for this initial condition. The stable K = 4 case reaches its model limit after one update and still misses the target.

Test the result

Substitute y[0] into the K = 4 recurrence. The first two outputs are both 8, two units below target.

Change an assumption

The sensor is two units high

Use K = 4 and keep the plant and target unchanged, but supply the controller with m[k] = y[k] + 2. Find the true output, the displayed output and both errors after convergence.

  1. Substitution gives y[k+1] = 0.8y[k] + 0.8(8 − y[k]) = 6.4. The fixed sensor offset changed the constant term and left the pole at zero.
  2. The sensor displays 6.4 + 2 = 8.4. Relative to the target, the true error is 3.6 and the displayed error is 1.6.

Answer and interpretation

The system still converges in one update. The reading suggests a smaller error even though the true tracking error has grown from 2 to 3.6.

Test the result

An independent position reference would reveal the discrepancy between the reading and the true position.

Common mistakes

Using the continuous stability rule

For this recurrence, |p|<1 is the relevant test. A negative pole such as −1.2 can still be unstable.

Calling a stable system accurate

Solve for the equilibrium and subtract it from the reference. The pole alone tells you how deviations evolve.

Treating the sensor as ground truth

Write a separate measurement equation and check it against an independent reference before interpreting a small displayed error.

Before moving on

  • Explain separately the signal readout, controller input and true output.
  • Derive the discrete pole and steady tracking error for the modeled gains.
  • State why sensor bias and joint coupling need separate checks before transferring the model.

Sources and edition checks

Sources checked:

These are proposed study activities, not official course assignments or a claim that every book has been read cover to cover.

How we curate →